A new or refurbished facility needs a server or network room ready for real operations.
Critical facility engineering
Server Rooms, Network Rooms & Data Centers
We combine compute, network and facility engineering into one system: racks and cabling, power and UPS, cooling, monitoring, physical security, documentation and ongoing support.
Discuss a project ↗︎Value
What your
business gets
One accountable team for the facility
Resilience aligned with actual criticality
Capacity for growth and maintenance
Documented and tested operations
When it fits
Situations where the service creates value
We start with the operating situation, constraints and the result that must change for the business — not with a technology list.
The current site is overloaded, undocumented or unable to provide the required resilience.
The customer needs one accountable party for racks, networks, power, cooling, monitoring and commissioning.
Included in the solution
We assemble the required
configuration.
Facility concept and design
We define capacity, resilience and growth requirements, then produce the concept, engineering decisions and phased delivery plan.
Racks, structured cabling and network rooms
We organize racks, copper and fiber routes, patching, labeling and an as-built topology that operations can actually use.
Power, UPS and cooling
We size power, resilience, UPS and heat removal, coordinating regulated work with appropriately authorized organizations.
Monitoring, security and commissioning
We implement environmental, leak, power and access monitoring, run integrated tests and hand over a complete as-built documentation set.
Delivery in detail
What we agree before work begins
Scope follows the site survey: server or network room, modular facility or data center; required capacity, resilience, facility systems, security and delivery stages. Regulated work is performed with appropriately authorized organizations.
Inputs include plans and room characteristics, available power and routes, the future equipment list, availability requirements, building constraints, schedule and existing design documentation.
We perform functional and failure tests covering power switching, cooling under load, monitoring, alarms, connectivity, labeling and the complete as-built documentation set.
After commissioning we organize inspections, facility monitoring, capacity management, resilience tests and technical support.
Process
Three steps
to launch.
Survey
We assess space, capacity, routes, cooling, risks and availability requirements.
Deliver
We engineer, supply and coordinate installation and commissioning work.
Commission
We test the facility, prepare as-built documents and hand it over to operations.
Solution: Server Rooms, Network Rooms & Data Centers