UPS CONFIGURATOR

Protected power
sized for the real load

Define equipment, runtime and redundancy. The configurator calculates power, phases and battery modules, then matches compatible Virtek solutions.

NORMATIVE REFERENCES

Standards and frameworks

We consider applicable requirements when designing architecture, controls and test programmes.

IEC · 62040-1Standard · INT
StandardCurrent

IEC 62040-1:2017 · UPS safety requirements

International reference for safe UPS design and use.

Jurisdiction
INT
Reviewed
2026-08-27
A design reference. Applicability and the extent of requirements are determined for each project.Official sourceOpen ↗︎
IEC · 62040-3Standard · INT
StandardCurrent

IEC 62040-3:2021 · UPS performance and test requirements

Reference for comparing declared performance and test scenarios.

Jurisdiction
INT
Reviewed
2026-08-27
A design reference. Applicability and the extent of requirements are determined for each project.Official sourceOpen ↗︎

Use case

What needs protection

Load

Enter equipment consumption

Calculated load6,500 W
Including starting modes6,500 W
Engineering headroom · 25%8,125 W

Requirements

Define the power system

CriticalityDouble conversion / modular · N+1 · from 15 minutes
TopologyAutomatic: Online double conversion
Input / output phaseAutomatic: 1/1
Form factor2 compatible models
Battery typeLower acquisition cost with scheduled battery replacement.
Required runtime
Automatic: ≥ 15 min
RedundancyDouble conversion / modular · N+1 · from 15 minutes
UPS / module quantity
3
Parallel N+1 · spare UPS
Selection logic

The controls are connected: changing criticality, topology or battery immediately updates phases, redundancy, runtime and matching solutions.

  1. Use caseServer rack
  2. CriticalityContinuous operation
  3. TopologyOnline double conversion
  4. Input / output phase1/1
  5. RedundancyParallel N+1 · spare UPS
  6. Battery typeVRLA · 15 min
Requirements applied — review auxiliary systems

AUXILIARY SYSTEMS

Extend the protected-power chain

Optional items. Select any one or several in any order; recommendations follow the active UPS scenario.

Current scenarioServer rack8,125 W · 1 / 1 · 3 UPS
INVOptional

Voltage regulator

Protects the UPS input from long sags, overvoltage and an unstable utility.

ESPOptional

Generator

Extends backup beyond UPS batteries during long utility outages.

MANAGEDOptional

Rack PDU

Distributes, meters and remotely controls power within the rack.

Auxiliary systems applied — continue to UPS selection

Selection result

Compatible solutions

Required capacity8,125 W · 9,029 VAWorst-case load per UPS4,063 W
Continue for the solution scope and calculation request

The rating is selected from calculated power, phases, runtime, form factor and support for the requested redundancy design.

Virtek Online

Virtek Online 6000

VTK-ON-6000

Topology
Online double conversion
Input / output phase
1/1
Required capacity
6,000 VA / 6,000 W
Efficiency
96%
Form factor
Rack / tower · Tower
Battery type
VRLA · Lithium-ion
  • ✓ Pure sine wave
  • ✓ Monitoring interface
  • ✓ Cold start

Solution scope

UPSVirtek Online 6000 × 3

Battery modules1 × 3

Maintenance bypassIncluded in estimate

Network monitoringIncluded in estimate

VIRTEK PROJECT

Project cart

Servers, UPS systems, workspaces and services in one engineering request

…

UPS CONFIGURATOR

Custom protected-power system

Describe the equipment, utility, runtime, redundancy and site constraints. Plain language is fine; our engineer will clarify missing details.